Transforms, Motors, Battery chargers, Power supplies, appliances, extra low voltage systems, machinery.
Current rating range:3~16A
Input voltage rating :125/250VAC; 50VDC
Interrupting Capacity : 125/250VAC x 1,000A(UL 1077)
Dielectric Strength:> 1.500VAC/min.
Insulation Resistance:>100MOHM (DC 500V)
Degree of protection:Terminal area IP00, operating area IP40
Mechanical/Environmental Data for Overload Protector Rocker Switch
Operating Ambient Temperature: -10ºC to +60ºC
Mounting: Various options. See Ordering Information and drawings
Termination: 250''(6.35mm)quick connects or solder terminals
Calibration(at25ºC) for Overload Protector Rocker Switch
100% of Rated Current: Hold ,No Trip
300% of Rated Current: Trip Within 1 Hour.
200% of Rated Current: 5-30 sec Trip
150% of Rated Current: Trip Within 1 Hour
Jfjk